Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
1.
J Plast Reconstr Aesthet Surg ; 91: 241-248, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38428232

RESUMO

Zygomaticomaxillary complex (ZMC) fracture repair is one of the most common surgical procedures performed in craniomaxillofacial trauma management. Miniplates and screws are used to stabilize the fractured bone using small local incisions, however, these procedures are not infrequently associated with hardware-related post-operative complications. The amount of fixation hardware utilized varies depending on the fracture pattern and surgical judgment, with three-point fixation being the conventionally accepted treatment. However, limited experimental testing and clinical studies have suggested that ZMC stabilization may be achieved with less than three-point fixation. In this study, we utilized a previously developed finite element modeling approach that allows for detailed bone and muscle representation to study the mechanical behavior of the fractured craniomaxillofacial skeleton (CMFS) under one, two, or three-point fixation of the ZMC. Results suggest that using a miniplate along the infraorbital rim in three-point fixation increases the amount of strain and load transfer to this region, rather than offloading the bone. Two-point (zygomaticomaxillary and zygomaticofrontal) fixation yielded strain patterns most similar to the intact CMFS. One-point (zygomaticofrontal) fixation resulted in higher tensile and compressive strains in the zygomaticofrontal region and the zygomatic arch, along with a higher tensile strain on the zygomatic body. These modeling results provide biomechanical evidence for the concept of over-engineering in the stabilization of facial fractures. Furthermore, they support previous suggestions that less than three-point fixation of ZMC fractures may be adequate to achieve uneventful healing.


Assuntos
Fraturas Cranianas , Fraturas Zigomáticas , Humanos , Fraturas Zigomáticas/cirurgia , Ossos Faciais , Zigoma/cirurgia , Fixação Interna de Fraturas/métodos
2.
J Mech Behav Biomed Mater ; 151: 106382, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38211499

RESUMO

Bone turnover and microdamage are impacted by the presence of skeletal metastases which can contribute to increased fracture risk. Treatments for metastatic disease may further impact bone quality. This exploratory study aimed to establish an initial understanding of microdamage accumulation and load to failure in healthy and osteolytic rat vertebrae following focal and systemic cancer treatment (docetaxel (DTX), stereotactic body radiotherapy (SBRT), or zoledronic acid (ZA)). Osteolytic spine metastases were developed in 6-week-old athymic female rats via intracardiac injection of HeLa human cervical cancer cells (day 0). Additional rats served as healthy controls. Rats were either untreated, received SBRT to the T10-L6 vertebrae on day 14 (15 Gy, two fractions), DTX on day 7 or 14, or ZA on day 7. Rats were euthanized on day 21. Tumor burden was assessed with bioluminescence images acquired on day 14 and 21, histology of the excised T11 and L5 vertebrae, and ex-vivo µCT images of the T13-L4. Microstructural parameters (bone volume/total volume, trabecular number, spacing, thickness, and bone mineral density) were measured from L2 vertebrae. Load to failure was measured with axial compressive loading of the L1-L3 motion segments. Microdamage accumulation was labeled in T13 vertebrae with BaSO4 staining and was visualized with high resolution µCT imaging. Microdamage volume fraction was defined as the ratio of BaSO4 to bone volume. DTX administered on day 7 reduced tumor growth significantly (p < 0.05). Microdamage accumulation was found to be increased by the presence of metastases but was reduced by all treatments with ZA showing the largest improvement in HeLa cell injected rats. Load to failure was decreased in untreated and SBRT HeLa cell injected rats compared to healthy controls (p < 0.01). There was a moderate negative correlation between load to failure and microdamage volume fraction in vertebrae from rats injected with HeLa cells (R = -0.35, p = 0.031). Strong correlations were also found between microstructural parameters and load to failure and microdamage accumulation. Several factors, including the presence of osteolytic lesions and use of cancer therapies, influence microdamage accumulation and load to failure in rat vertebrae. Understanding the impact of these treatments on fracture risk of metastatic vertebrae is important to improve management of patients with spinal metastases.


Assuntos
Fraturas Ósseas , Vértebras Lombares , Ratos , Humanos , Feminino , Animais , Células HeLa , Vértebras Lombares/patologia , Densidade Óssea , Fraturas Ósseas/patologia , Vértebras Torácicas
3.
J Craniofac Surg ; 34(6): 1727-1731, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37552131

RESUMO

INTRODUCTION: Orbital blowout fractures are commonly reconstructed with implants shaped to repair orbital cavity defects, restore ocular position and projection, and correct diplopia. Orbital implant shaping has traditionally been performed manually by surgeons, with more recent use of computer-assisted design (CAD). Accuracy of implant placement is also key to reconstruction. This study compares the placement accuracy of orbital implants, testing the hypothesis that CAD-shaped implants indexed to patient anatomy will better restore orbit geometry compared with manually shaped implants and manually placed implants. METHODS: The placement accuracy of orbital implants was assessed within a cadaveric blowout fracture model (3 skulls, 6 orbits) via 3-dimensional CT analysis. Defects were repaired with 4 different techniques: manually placed-manually shaped composite (titanium-reinforced porous polyethylene), manually placed CAD composite, indexed placed CAD composite, and indexed placed CAD titanium mesh. RESULTS: Implant placement accuracy differed significantly with the implant preparation method ( P =0.01). Indexing significantly improved the placement accuracy ( P =0.002). Indexed placed titanium mesh CAD implants (1.42±0.33 mm) were positioned significantly closer to the intact surface versus manually placed-manually shaped composite implants (2.12±0.39 mm). DISCUSSION: Computer-assisted design implants indexed to patient geometry yielded average errors below the acceptable threshold (2 mm) for enophthalmos and diplopia. This study highlights the importance of adequately indexing CAD-designed implants to patient geometry to ensure accurate orbital reconstructions.


Assuntos
Implantes Dentários , Enoftalmia , Fraturas Orbitárias , Procedimentos de Cirurgia Plástica , Humanos , Diplopia/cirurgia , Titânio , Órbita/diagnóstico por imagem , Órbita/cirurgia , Enoftalmia/cirurgia , Polietileno , Cadáver , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/cirurgia
4.
J Craniofac Surg ; 34(7): 1915-1921, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37639641

RESUMO

Reconstructing facial deformities is often challenging due to the complex 3-dimensional (3D) anatomy of the craniomaxillofacial skeleton and overlying soft tissue structures. Bilateral injuries cannot benefit from mirroring techniques and as such preinjury information (eg, 2D pictures or 3D imaging) may be utilized to determine or estimate the desired 3D face shape. When patient-specific information is not available, other options such as statistical shape models may be employed; however, these models require registration to a consistent orientation which may be challenging. Artificial intelligence (AI) has been used to identify facial features and generate highly realistic simulated faces. As such, it was hypothesized that AI can be used to predict 3D face shape by learning its relationship with the underlying bone surface anatomy in a subject-specific manner. An automated image processing and AI modeling workflow using a modified 3D UNet was generated to estimate 3D face shape using the underlying bone geometry and additional metadata (eg, body mass index and age) obtained from 5 publicly available computed tomography imaging datasets. Visually, the trained models provided a reasonable prediction of the contour and geometry of the facial tissues. The pipeline achieved a validation dice=0.89 when trained on the combined 5 datasets, with the highest dice=0.925 achieved with the single HNSCC dataset. Estimated predefect facial geometry may ultimately be used to aid preoperative craniomaxillofacial surgical planning, providing geometries for intraoperative templates, guides, navigation, molds, and forming tools. Automated face shape prediction may additionally be useful in forensic studies to aid in the identification of unknown skull remains.

5.
Med Image Anal ; 88: 102865, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37331241

RESUMO

Cranial implants are commonly used for surgical repair of craniectomy-induced skull defects. These implants are usually generated offline and may require days to weeks to be available. An automated implant design process combined with onsite manufacturing facilities can guarantee immediate implant availability and avoid secondary intervention. To address this need, the AutoImplant II challenge was organized in conjunction with MICCAI 2021, catering for the unmet clinical and computational requirements of automatic cranial implant design. The first edition of AutoImplant (AutoImplant I, 2020) demonstrated the general capabilities and effectiveness of data-driven approaches, including deep learning, for a skull shape completion task on synthetic defects. The second AutoImplant challenge (i.e., AutoImplant II, 2021) built upon the first by adding real clinical craniectomy cases as well as additional synthetic imaging data. The AutoImplant II challenge consisted of three tracks. Tracks 1 and 3 used skull images with synthetic defects to evaluate the ability of submitted approaches to generate implants that recreate the original skull shape. Track 3 consisted of the data from the first challenge (i.e., 100 cases for training, and 110 for evaluation), and Track 1 provided 570 training and 100 validation cases aimed at evaluating skull shape completion algorithms at diverse defect patterns. Track 2 also made progress over the first challenge by providing 11 clinically defective skulls and evaluating the submitted implant designs on these clinical cases. The submitted designs were evaluated quantitatively against imaging data from post-craniectomy as well as by an experienced neurosurgeon. Submissions to these challenge tasks made substantial progress in addressing issues such as generalizability, computational efficiency, data augmentation, and implant refinement. This paper serves as a comprehensive summary and comparison of the submissions to the AutoImplant II challenge. Codes and models are available at https://github.com/Jianningli/Autoimplant_II.


Assuntos
Próteses e Implantes , Crânio , Humanos , Crânio/diagnóstico por imagem , Crânio/cirurgia , Craniotomia/métodos , Cabeça
6.
J Plast Reconstr Aesthet Surg ; 84: 47-53, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37320951

RESUMO

Fixation is critical in zygomaticomaxillary complex (ZMC) fractures to avoid malunion; however, controversy exists as to how much hardware is required to achieve adequate stability. Current fixation regimens may not represent the minimum stabilization needed for uneventful healing. Craniomaxillofacial (CMF) computational models have shown limited load transmission through the infraorbital rim (IOR), and a previous experimental study of ZMC fractures has suggested that IOR plating does not alter CMF bone strain patterns. This study aimed to measure the impact of stabilization on fracture site displacement under muscle loading, testing the hypothesis that three-point fixation is not critical for ZMC fracture stability. Four ZMC complex fractures were simulated on two cadaveric samples and stabilized with three-point plating. Displacements simulating mouth openings of 20 mm and 30 mm were applied to the mandible using a custom apparatus. Fracture gap displacement under load was measured at multiple points along each fracture line, and bone strain was captured using a combination of uniaxial and rosette gauges. Data capture was repeated with the IOR plate removed (two-point fixation) and with the zygomaticomaxillary plate removed (one-point fixation). Fracture displacement under muscle loading was consistent, with gaps of less than 1 mm in 95% of cases (range 0.05-1.44 mm), reflecting clinical stability. Large variabilities were observed in the strain measurements, which may reflect the complexity of CMFS load patterns and the sensitivity of strain values to gauge placement. This study supports the concept of hardware reduction, suggesting that two-point (or even one-point) fixation may provide sufficient stability for a ZMC fracture under applied muscle loading.


Assuntos
Fraturas Maxilares , Procedimentos de Cirurgia Plástica , Fraturas Zigomáticas , Humanos , Fraturas Zigomáticas/cirurgia , Fixação Interna de Fraturas , Placas Ósseas , Mandíbula/cirurgia , Fraturas Maxilares/cirurgia
7.
Int J Comput Assist Radiol Surg ; 18(12): 2339-2347, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37245180

RESUMO

PURPOSE: Bone-targeted radiofrequency ablation (RFA) is widely used in the treatment of vertebral metastases. While radiation therapy utilizes established treatment planning systems (TPS) based on multimodal imaging to optimize treatment volumes, current RFA of vertebral metastases has been limited to qualitative image-based assessment of tumour location to direct probe selection and access. This study aimed to design, develop and evaluate a computational patient-specific RFA TPS for vertebral metastases. METHODS: A TPS was developed on the open-source 3D slicer platform, including procedural setup, dose calculation (based on finite element modelling), and analysis/visualization modules. Usability testing was carried out by 7 clinicians involved in the treatment of vertebral metastases on retrospective clinical imaging data using a simplified dose calculation engine. In vivo evaluation was performed in a preclinical porcine model (n = 6 vertebrae). RESULTS: Dose analysis was successfully performed, with generation and display of thermal dose volumes, thermal damage, dose volume histograms and isodose contours. Usability testing showed an overall positive response to the TPS as beneficial to safe and effective RFA. The in vivo porcine study showed good agreement between the manually segmented thermally damaged volumes vs. the damage volumes identified from the TPS (Dice Similarity Coefficient = 0.71 ± 0.03, Hausdorff distance = 1.2 ± 0.1 mm). CONCLUSION: A TPS specifically dedicated to RFA in the bony spine could help account for tissue heterogeneities in both thermal and electrical properties. A TPS would enable visualization of damage volumes in 2D and 3D, assisting clinicians in decisions about potential safety and effectiveness prior to performing RFA in the metastatic spine.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Humanos , Suínos , Animais , Estudos Retrospectivos , Coluna Vertebral , Ablação por Radiofrequência/métodos , Ablação por Cateter/métodos
8.
Clin Genitourin Cancer ; 21(4): e228-e235.e1, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36849325

RESUMO

INTRODUCTION: Osteosarcopenia is the progressive loss of musculoskeletal structure and functionality, contributing to disability and mortality. Despite complex interactions between bone and muscle, osteosarcopenia prevention and treatment in men with metastatic castration-resistant prostate cancer (mCRPC) focuses predominantly on bone health. It is unknown whether Radium-223 (Ra-223) therapy affects sarcopenia. METHODS: We identified 52 patients with mCRPC who had received Ra-223 and had a baseline plus ≥1 follow-up abdominopelvic CT scan. The total contour area (TCA) and averaged Hounsfield units (HU) of the left and right psoas muscles were obtained at the inferior L3 endplate, and the psoas muscle index (PMI) was calculated therefrom. Intrapatient musculoskeletal changes were analyzed across various time points. RESULTS: TCA and PMI gradually declined over the study period (P = .002, P = .003, respectively), but Ra-223 therapy did not accelerate sarcopenia, nor the decline of HU compared to the pre-Ra-223 period. The median overall survival of patients with baseline sarcopenia was numerically worse (14.93 vs. 23.23 months, HR 0.612, P = .198). CONCLUSIONS: Ra-223 does not accelerate sarcopenia. Thus, worsening muscle parameters in men with mCRPC undergoing Ra-223 therapy are attributable to other factors. Further research is needed to determine whether baseline sarcopenia predicts poor overall survival in such patients.


Assuntos
Neoplasias Ósseas , Neoplasias de Próstata Resistentes à Castração , Rádio (Elemento) , Sarcopenia , Masculino , Humanos , Neoplasias de Próstata Resistentes à Castração/patologia , Sarcopenia/diagnóstico por imagem , Sarcopenia/etiologia , Neoplasias Ósseas/radioterapia , Neoplasias Ósseas/secundário , Estudos Retrospectivos
9.
J Craniofac Surg ; 34(1): 177-180, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36084214

RESUMO

BACKGROUND: The challenge of assessing nasal alignment and asymmetry can contribute to high revision rates in rhinoplasty. Comparing to a validated computer algorithm for nasal alignment, the accuracy with which plastic surgeons can assess deviation of the nasal midline from the facial midline was measured. METHODS: Using 20 faces from the Binghamton University 3-dimensional face database, deviation was evaluated from facial midline of the middorsal line for the upper, middle, and lower thirds of the nose. Surgeons were asked to assess extent of deviation from facial midline for each third of the nose using a linear analog scale. Spearman correlations were performed comparing the surgeons' results to the algorithm measurements. Eleven residents and 9 consultant surgeons were tested. RESULTS: Surgeons' assessment of deviation correlated poorly with the algorithm in the upper third ( r =0.32, P <0.0001) and moderately in the middle third ( r =0.49, P <0.0001) and lower third ( r =0.41, P <0.0001) of the nose. No difference in accuracy was found between trainee and consultant surgeons ( P =0.51), and greater experience (>10 y performing nasal surgery) did not significantly affect performance ( P =0.15). The effect of fatigue on the accuracy of assessment was found to be significant ( P =0.0009). CONCLUSIONS: Surgeons have difficulty in visually assessing the 3-dimensional nasal midline irrespective of experience, and surgeon fatigue was found to be adversely affect the accuracy of assessments.


Assuntos
Deformidades Adquiridas Nasais , Rinoplastia , Cirurgiões , Humanos , Rinoplastia/métodos , Estética Dentária , Nariz/cirurgia , Deformidades Adquiridas Nasais/cirurgia
10.
Sci Rep ; 12(1): 14438, 2022 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-36002557

RESUMO

The lack of therapeutic options to fight Covid-19 has contributed to the current global pandemic. Despite the emergence of effective vaccines, development of broad-spectrum antiviral treatment remains a significant challenge, in which antimicrobial photodynamic therapy (aPDT) may play a role, especially at early stages of infection. aPDT of the nares with methylene blue (MB) and non-thermal light has been successfully utilized to inactivate both bacterial and viral pathogens in the perioperative setting. Here, we investigated the effect of MB-aPDT to inactivate human betacoronavirus OC43 and SARS-CoV-2 in vitro and in a proof-of-principle COVID-19 clinical trial to test, in a variety of settings, the practicality, technical feasibility, and short-term efficacy of the method. aPDT yielded inactivation of up to 6-Logs in vitro, as measured by RT-qPCR and infectivity assay. From a photo-physics perspective, the in vitro results suggest that the response is not dependent on the virus itself, motivating potential use of aPDT for local destruction of SARS-CoV-2 and its variants. In the clinical trial we observed variable effects on viral RNA in nasal-swab samples as assessed by RT-qPCR attributed to aPDT-induced RNA fragmentation causing falsely-elevated counts. However, the viral infectivity in clinical nares swabs was reduced in 90% of samples and undetectable in 70% of samples. This is the first demonstration based on quantitative clinical viral infectivity measurements that MB-aPDT is a safe, easily delivered and effective front-line technique that can reduce local SARS-CoV-2 viral load.


Assuntos
Tratamento Farmacológico da COVID-19 , Desinfecção , Nariz , Fotoquimioterapia , Anti-Infecciosos/efeitos adversos , Anti-Infecciosos/farmacologia , Desinfecção/métodos , Estudos de Viabilidade , Humanos , Azul de Metileno/efeitos adversos , Azul de Metileno/farmacologia , Nariz/virologia , Pandemias , RNA Viral/análise , SARS-CoV-2/efeitos dos fármacos , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Resultado do Tratamento , Carga Viral/efeitos dos fármacos
11.
Clin Exp Metastasis ; 39(5): 833-840, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35819644

RESUMO

Bone remodeling is disrupted in the presence of metastases and can present as osteolytic, osteoblastic or a mixture of the two. Established rat models of osteolytic and mixed metastases have been identified changes in structural and tissue-level properties of bone. The aim of this work was to establish a preclinical rat model of osteoblastic metastases and characterize bone quality changes through image-based evaluation. Female athymic rats (n = 22) were inoculated with human breast cancer cells ZR-75-1 and tumor development tracked over 3-4 months with bioluminescence and in-vivo µCT imaging. Bone tissue-level stereological features were quantified on ex-vivo µCT imaging. Histopathology verified the presence of osteoblastic bone. Bone mineral density distribution was assessed via backscattered electron microscopy. Newly formed osteoblastic bone was associated with reduced mineral content and increased heterogeneity leading to an overall degraded bone quality. Characterizing changes in osteoblastic bone properties is relevant to pre-clinical therapeutic testing and treatment planning.


Assuntos
Neoplasias Ósseas , Animais , Densidade Óssea , Neoplasias Ósseas/patologia , Remodelação Óssea , Osso e Ossos , Feminino , Humanos , Osteoblastos/metabolismo , Ratos , Ratos Nus
12.
Int J Comput Assist Radiol Surg ; 17(7): 1191-1199, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35633491

RESUMO

PURPOSE: External ventricular drainage (EVD) is a life-saving procedure indicated for elevated intracranial pressure. A catheter is inserted into the ventricles to drain cerebrospinal fluid and release the pressure on the brain. However, the standard freehand EVD technique results in catheter malpositioning in up to 60.1% of procedures. This proof-of-concept study aimed to evaluate the registration accuracy of a novel image-based verification system "Bullseye EVD" in a preclinical cadaveric model of catheter placement. METHODS: Experimentation was performed on both sides of 3 cadaveric heads (n = 6). After a pre-interventional CT scan, a guidewire simulating the EVD catheter was inserted as in a clinical EVD procedure. 3D structured light images (Einscan, Shining 3D, China) were acquired of an optical tracker placed over the guidewire on the surface of the scalp, along with three distinct cranial regions (scalp, face, and ear). A computer vision algorithm was employed to determine the guidewire position based on the pre-interventional CT scan and the intra-procedural optical imaging. A post-interventional CT scan was used to validate the performance of the Bullseye optical imaging system in terms of trajectory and offset errors. RESULTS: Optical images which combined facial features and exposed scalp within the surgical field resulted in the lowest trajectory and offset errors of 1.28° ± 0.38° and 0.33 ± 0.19 mm, respectively. Mean duration of the optical imaging procedure was 128 ± 35 s. CONCLUSIONS: The Bullseye EVD system presents an accurate patient-specific method to verify freehand EVD positioning. Use of facial features was critical to registration accuracy. Workflow automation and development of a user interface must be considered for future clinical evaluation.


Assuntos
Doença pelo Vírus Ebola , Cadáver , Catéteres , Ventrículos Cerebrais/diagnóstico por imagem , Ventrículos Cerebrais/cirurgia , Drenagem/métodos , Humanos
13.
J Med Eng Technol ; 46(1): 46-58, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34678121

RESUMO

Intramedullary (IM) nailing is the standard of care for adult lower extremity long bone fracture stabilisation. Key to this procedure is obtaining the correct entry point and trajectory for initial guide pin insertion. This work presents the Femoral Antegrade Starting Tool (FAST), a surgical tool that addresses the lack of connectivity in utilising sequential 2D fluoroscopic images to achieve 3D alignment of femoral guide pin placement. The user centred design and development of FAST is introduced and the performance of this device evaluated during guide pin insertion for femoral IM nailing in a series of sawbones and cadaveric models leading to a first in human clinical cohort study. The results demonstrated the potential of FAST to improve time and consistency of the guide pin insertion for femoral IM nailing for less experienced surgeons and trainees. Overall, FAST was found to be easy to use with a high degree of clinical interest (particularly for use in large patients) and acceptance motivating continued development of this new technology.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Adulto , Pinos Ortopédicos , Estudos de Coortes , Fraturas do Fêmur/cirurgia , Humanos , Extremidade Inferior , Resultado do Tratamento
14.
J Craniofac Surg ; 33(1): e78-e80, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34967530

RESUMO

ABSTRACT: The forehead flap is the gold standard procedure for nasal reconstruction to address a partial or complete rhinectomy. Traditionally, the three-dimensional (3D) nasal defect is manually templated intraoperatively to design the two-dimensional (2D) flap shape on intact morphology. In this clinical study, digital preoperative planning is used to template with computer-assisted design and manufacturing. Preoperative digital templates were implemented for 3 representative patients (1 in Supplementary Digital Content, http://links.lww.com/SCS/D60). This includes designs for a hemi-rhinectomy case from 3D mirroring, a partial total rhinectomy case generated from a 3D scan, and a total rhinectomy case generated from a 3D morphable model based on a prepathology 2D photo. Digital unwrapping flattened the patient's 3D nasal geometry designs to 2D skin flap shapes. Finally, the 2D designs were printed as traceable intraoperative templates at a 1:1 scale. This clinical study demonstrates the application of digital 3D preoperative templating to improve workflow for nasal reconstruction.


Assuntos
Testa , Nariz , Desenho Assistido por Computador , Testa/diagnóstico por imagem , Testa/cirurgia , Humanos , Imageamento Tridimensional , Nariz/diagnóstico por imagem , Nariz/cirurgia , Retalhos Cirúrgicos
15.
Bone Jt Open ; 2(11): 1004-1016, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34825826

RESUMO

AIMS: This study investigates head-neck taper corrosion with varying head size in a novel hip simulator instrumented to measure corrosion related electrical activity under torsional loads. METHODS: In all, six 28 mm and six 36 mm titanium stem-cobalt chrome head pairs with polyethylene sockets were tested in a novel instrumented hip simulator. Samples were tested using simulated gait data with incremental increasing loads to determine corrosion onset load and electrochemical activity. Half of each head size group were then cycled with simulated gait and the other half with gait compression only. Damage was measured by area and maximum linear wear depth. RESULTS: Overall, 36 mm heads had lower corrosion onset load (p = 0.009) and change in open circuit potential (OCP) during simulated gait with (p = 0.006) and without joint movement (p = 0.004). Discontinuing gait's joint movement decreased corrosion currents (p = 0.042); however, wear testing showed no significant effect of joint movement on taper damage. In addition, 36 mm heads had greater corrosion area (p = 0.050), but no significant difference was found for maximum linear wear depth (p = 0.155). CONCLUSION: Larger heads are more susceptible to taper corrosion; however, not due to frictional torque as hypothesized. An alternative hypothesis of taper flexural rigidity differential is proposed. Further studies are necessary to investigate the clinical significance and underlying mechanism of this finding. Cite this article: Bone Jt Open 2021;2(11):1004-1016.

16.
PLoS One ; 16(9): e0256076, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34495961

RESUMO

Thermal therapies such as radiofrequency ablation (RFA) are gaining widespread clinical adoption in the local treatment of skeletal metastases. RFA has been shown to successfully destroy tumor cells, yet the impact of RFA on the quality of the surrounding bone has not been well characterized. RFA treatment was performed on femora of rats with bone metastases (osteolytic and osteoblastic) and healthy age matched rats. Histopathology, second harmonic generation imaging and backscatter electron imaging were used to characterize changes in the structure, organic and mineral components of the bone after RFA. RFA treatment was shown to be effective in targeting tumor cells and promoting subsequent new bone formation without impacting the surrounding bone negatively. Mineralization profiles of metastatic models were significantly improved post-RFA treatment with respect to mineral content and homogeneity, suggesting a positive impact of RFA treatment on the quality of cancer involved bone. Evaluating the impact of RFA on bone quality is important in directing the growth of this minimally invasive therapeutic approach with respect to fracture risk assessment, patient selection, and multimodal treatment planning.


Assuntos
Neoplasias Ósseas/secundário , Neoplasias Ósseas/cirurgia , Calcificação Fisiológica , Neoplasias Mamárias Experimentais/cirurgia , Ablação por Radiofrequência , Animais , Neoplasias Ósseas/metabolismo , Modelos Animais de Doenças , Feminino , Neoplasias Mamárias Experimentais/metabolismo , Neoplasias Mamárias Experimentais/patologia , Ratos , Ratos Nus , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
Sci Rep ; 11(1): 17871, 2021 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-34504208

RESUMO

Spinal metastases often occur in the advanced stages of breast, lung or prostate cancer, resulting in a significant impact on the patient's quality of life. Current treatment modalities for spinal metastases include both systemic and localized treatments that aim to decrease pain, improve mobility and structural stability, and control tumour growth. With the development of non-toxic photosensitizer drugs, photodynamic therapy (PDT) has shown promise as a minimally invasive non-thermal alternative in oncology, including for spinal metastases. To apply PDT to spinal metastases, predictive algorithms that optimize tumour treatment and minimize the risk of spinal cord damage are needed to assess the feasibility of the treatment and encourage a broad acceptance of PDT in clinical trials. This work presents a framework for PDT modelling and planning, and simulates the feasibility of using a BPD-MA mediated PDT to treat bone metastases at two different wavelengths (690 nm and 565 nm). An open-source software for PDT planning, PDT-SPACE, is used to evaluate different configurations of light diffusers (cut-end and cylindrical) fibres with optimized power allocation in order to minimize the damage to spinal cord or maximize tumour destruction. The work is simulated on three CT images of metastatically involved vertebrae acquired from three patients with spinal metastases secondary to colorectal or lung cancer. Simulation results show that PDT at a 565 nm wavelength has the ability to treat 90% of the metastatic lesion with less than 17% damage to the spinal cord. However, the energy required, and hence treatment time, to achieve this outcome with the 565 nm is infeasible. The energy required and treatment time for the longer wavelength of 690 nm is feasible ([Formula: see text] min), but treatment aimed at 90% of the metastatic lesion would severely damage the proximal spinal cord. PDT-SPACE provides a simulation platform that can be used to optimize PDT delivery in the metastatic spine. While this work serves as a prospective methodology to analyze the feasibility of PDT for tumour ablation in the spine, preclinical studies in an animal model are ongoing to elucidate the spinal cord damage extent as a function of PDT dose, and the resulting short and long term functional impairments. These will be required before there can be any consideration of clinical trials.


Assuntos
Metástase Neoplásica/patologia , Fotoquimioterapia , Fármacos Fotossensibilizantes/uso terapêutico , Neoplasias da Coluna Vertebral/terapia , Humanos , Fotoquimioterapia/métodos , Estudos Prospectivos , Qualidade de Vida , Neoplasias da Coluna Vertebral/secundário , Coluna Vertebral/patologia , Verteporfina/uso terapêutico
18.
Curr Osteoporos Rep ; 18(6): 705-715, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33074529

RESUMO

PURPOSE OF REVIEW: Skeletal metastasis involves the uncoupling of physiologic bone remodeling resulting in abnormal bone turnover and radical changes in bony architecture, density, and quality. Bone strength assessment and fracture risk prediction are critical in clinical treatment decision-making. This review focuses on bone tissue and structural mechanisms altered by osteolytic metastasis and the resulting changes to its material and mechanical behavior. RECENT FINDINGS: Both organic and mineral phases of bone tissue are altered by osteolytic metastatic disease, with diminished bone quality evident at multiple length-scales. The mechanical performance of bone with osteolytic lesions is influenced by a combination of tissue-level and structural changes. This review considers the effects of osteolytic metastasis on bone biomechanics demonstrating its negative impact at tissue and structural levels. Future studies need to assess the cumulative impact of cancer treatments on metastatically involved bone quality, and its utility in directing multimodal treatment planning.


Assuntos
Neoplasias Ósseas/fisiopatologia , Neoplasias Ósseas/secundário , Osteólise/fisiopatologia , Animais , Fenômenos Biomecânicos , Humanos
19.
BMC Musculoskelet Disord ; 20(1): 389, 2019 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-31470828

RESUMO

BACKGROUND: Lithium, an established psychiatric medication, has recently been shown to enhance new bone formation in preclinical fracture models. Current research is focused on evaluating the efficacy of low-dose, short-term lithium treatment to improve long bone fracture healing through a Phase II randomized clinical trial (LiFT NCT02999022). In working towards future applications of lithium for fracture management, this study aimed to understand the current perceptions of lithium as a psychiatric drug and the potential barriers to its orthopaedic adoption. METHODS: Three questionnaires, evaluating knowledge about lithium and willingness to embrace its use in fracture healing were disseminated among the general population, fracture patients eligible for the LiFT (Lithium for Fracture Treatment) trial and orthopaedic surgeons across Canada. RESULTS: Of the 768 public respondents, 84% were willing to take a medication that would aid fracture healing but only 62.6% if the medication was lithium. Willingness dropped to 44.6% among the 168 respondents who knew about the psychiatric use of lithium. Lack of sufficient knowledge (n = 50) and concerns about side effects including effects on the brain (n = 74) were the main reasons cited by those who were unwilling to use lithium. Of the 29 fracture patients, only 20 patients had previously heard of lithium. Of these, 40% were willing to take lithium for fracture healing with an additional 10% if the dose was low or if the intake duration was short. Only 50% knew that lithium has side effects. Of the 43 orthopaedic surgeons, 38 surgeons knew about clinical use of lithium. Of these, 68% knew that lithium has side effects and 29% knew that it interacts with other drugs. While most agreed that new strategies are needed to improve fracture management, only 68% were willing to prescribe lithium for fractures with an additional 16% if there is scientific evidence and/or a standard dosing protocol. CONCLUSIONS: This study identified a lack of knowledge about uses and side effects of lithium among all three cohorts. A robust educational framework for orthopaedic surgeons, their patients and the members of their clinical care teams will be essential to widespread repurposing of lithium for fracture care.


Assuntos
Competência Clínica/estatística & dados numéricos , Consolidação da Fratura/efeitos dos fármacos , Fraturas Ósseas/terapia , Conhecimentos, Atitudes e Prática em Saúde , Carbonato de Lítio/administração & dosagem , Adolescente , Adulto , Encéfalo/efeitos dos fármacos , Canadá , Relação Dose-Resposta a Droga , Esquema de Medicação , Reposicionamento de Medicamentos , Feminino , Fixação de Fratura , Humanos , Carbonato de Lítio/efeitos adversos , Masculino , Pessoa de Meia-Idade , Cirurgiões Ortopédicos/psicologia , Cirurgiões Ortopédicos/estatística & dados numéricos , Percepção , Placebos/administração & dosagem , Placebos/efeitos adversos , Inquéritos e Questionários/estatística & dados numéricos , Fatores de Tempo , Adulto Jovem
20.
Shoulder Elbow ; 11(2 Suppl): 16-28, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31447941

RESUMO

BACKGROUND: Positioning of the glenoid component is one of the most challenging steps in shoulder arthroplasty, and prosthesis longevity as well as functional outcomes is considered highly dependent on accurate positioning. This review considers the evidence supporting surgical navigation and patient-specific instruments for glenoid implant positioning in anatomic and reverse total shoulder arthroplasty. METHODS: A systematic literature search was performed for studies assessing glenoid implant positioning accuracy as measured by cross-sectional imaging on live subjects or cadaver models. Meta-analysis of controlled studies was performed to estimate the primary effects of navigation and patient-specific instruments on glenoid implant positioning error. Meta-analysis of absolute positioning outcomes was also performed for each group incorporating data from controlled and uncontrolled studies. RESULTS: Nine studies, four controlled and five uncontrolled, with 258 total subjects were included in the analysis. Meta-analysis of controlled studies supported that both navigation and patient-specific instruments had a moderate statistically significant effect on improving glenoid implant positioning outcomes. Meta-analysis of absolute positioning outcomes demonstrates glenoid implant positioning with standard instrumentation results in a high rate of malposition. DISCUSSION: Navigation and patient-specific instruments improve glenoid positioning outcomes. Whether the improvement in positioning outcomes achieved translate to better clinical outcomes is unknown.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA